Category: Cogent Diamond Hydride Information
/
/
/
/
Sub Categories
Analyze phosphorylated compounds with the Cogent Diamond Hydride column - Tips & Suggestions
Read More
Read More
Are there HPLC columns that could be used to separate both polar and nonpolar compounds in a single run - FAQ
Read More
Read More
Assuring retention of polar compounds in an Aqueous Normal Phase ANP gradient in positive ion mode LCMS - Tips & Suggestions
Read More
Read More
Changing retention times of amino acids in biological extracts using ammonium acetate in HPLC methods. - Troubleshooting.
Read More
Read More
Glucose pyruvate taurocholic acid gamma glutamylcysteine and other analysis - Tips & Suggestions
Read More
Read More
High molecular weight compounds that won't retain on Cogent Diamond Hydride column try Cogent Bidentate C8 300 - Tips & Suggestions
Read More
Read More
High Pressure Develops after Flushing a Cogent Diamond Hydride HPLC Column with Acetonitrile Cause and Solution - FAQ
Read More
Read More
How Can I Get Separation of Tartaric and Malic Acid in a Complex Mixture - Tips & Suggestions
Read More
Read More
How do I Avoid Distorted Peak Shapes When Using a Basic Mobile Phase pH for the Analysis of a Lipophilic Amine - Tips & Suggestions
Read More
Read More
How to eliminate retention time drift in LCMS with Aqueous Normal Phase ANP methods - Tips & Suggestions
Read More
Read More
How to Get Improved Retention and Peak Shape for Glutamine Glutamic Acid and Aspartic Acid - Tips & Suggestions
Read More
Read More
How to improve peak shapes, retention & carryover for polar compounds with the Cogent Diamond Hydride™ column - Tips & Suggestions
Read More
Read More
How to keep the Cogent Diamond Hydride column clean when using blood as a sample - Tips & Suggestions
Read More
Read More
I am not observing any peaks for succinic acid or alpha-ketoglutarate with the Cogent Diamond Hydride column - Tips & Suggestions
Read More
Read More
Injection Technique for Aqueous Samples using Cogent TYPE-C Columns in ANP - Tips & Suggestions
Read More
Read More
Issues arising from changes in mobile phase with acids to one with ammonium salts. Tips & Suggestions
Read More
Read More
Lower retention is observed when functional group in a compound is ionized - Tips & Suggestions
Read More
Read More
Mobile Phase recommendation Cogent Diamond Hydride columns for use with serum samples in Aqueous Normal Phase LCMS - Tips & Suggestions
Read More
Read More
Modify selectivity in an ANP method of HPLC using different mobile phase pH - Tips & Suggestions
Read More
Read More
My LCMS source was getting white film on it and at the same time the background noise was very low so is my Diamond Hydride column bleeding packing material - FAQ
Read More
Read More
Restoring the initial results with a method for analyzing AMP ADP ATP UDP and GPT in biological extracts - Tips & Suggestions
Read More
Read More
Solving baseline problems in ANP methods with the Cogent Diamond Hydride column - Tips & Suggestions
Read More
Read More
Use a low concentration of salt in your mobile phase to avoid ion suppression and build up on your inlet source - Tips & Suggestions
Read More
Read More
Using two HPLC columns together in a tandem separation for polar and non polar retention - Tips & Suggestions
Read More
Read More
What are some notable examples of journal articles that feature Aqueous Normal Phase ANP methods in metabolomics studies - FAQ
Read More
Read More
What pressure should I expect with a Diamond Hydride 2.o HPLC column at flow rates from 0.2 to 2.0mL / min - FAQ
Read More
Read More
Which Cogent TYPE-C column do you recommend for the separation of positional isomers by HPLC or LCMS - FAQ
Read More
Read More
Which column do you suggest for Cocaine & metabolite Ecognin separation - Tips & Suggestions
Read More
Read More